Vacuum Interrupter With Cup-Type Electrode -Simulations of 3D Axial Magentic Filed and Eddy Current in the Contact
发布时间:2025-04-30
点击次数:
- 发布时间:
- 2025-04-30
- 论文名称:
- Vacuum Interrupter With Cup-Type Electrode -Simulations of 3D Axial Magentic Filed and Eddy Current in the Contact
- 发表刊物:
- ISDEIV 2000
- 摘要:
- Abstract Axial Magnetic Field (AMF) in a Vacuum
Interrupter (VI) with cup-type electrode is calculated,
which includes 3D static AMF, 3D harmonic AMF and
induced eddy current in contacts. The current in the
calculation is 1000A. The results show that harmonic
AMF is different with that of the static AMF because
eddy current exists. The eddy current influences the
AMF distribution in the center area of contact most
heavily, between the slots lightly, above the slots most
lightly.
- 合写作者:
- Liu Zhiyuan, Wang Jimei, Wang Zheng et al
- 卷号:
- XI'AN
- 页面范围:
- 459-462
- 是否译文:
- 否
- 发表时间:
- 2000-09-18