EN 登录
个人信息 更多+

胡华四

教授 博士生导师 硕士生导师

  • 电子邮箱:
  • 学历: 博士研究生毕业
  • 学位: 博士

论文成果

当前位置: 中文主页 - 科学研究 - 论文成果

Simulation Study of Using High-Z EMA to Suppress Recoil Protons Crosstalk in Scintillating Fiber Array for 14.1 MeV Neutron Imaging

发布时间:2025-04-30
点击次数:
发布时间:
2025-04-30
论文名称:
Simulation Study of Using High-Z EMA to Suppress Recoil Protons Crosstalk in Scintillating Fiber Array for 14.1 MeV Neutron Imaging
发表刊物:
IEEE Transactions on Nuclear Science
摘要:
Simulation Study of Using High-Z EMA to Suppress Recoil Protons Crosstalk in Scintillating Fiber Array for 14.1 MeV Neutron Imaging
This paper studies the effect of a high-Z extra mural absorber (EMA) to improve the spatial resolution of a plastic (polystyrene) scintillating fiber array for 14.1 MeV fusion neutron imaging. Crosstalk induced by recoil protons was studied, and platinum (Pt) was selected as EMA material, because of its excellent ability to suppress the recoil protons penetrating the fibers. Three common fiber arrays (cylindrical scintillating fibers in square and hexagonal packing arrangements and square scintillating fibers) were simulated using the Monte Carlo method for evaluating the effect of Pt-EMA in improving spatial resolution. It is found that the resolution of the 100 μm square fiber array can be improved from 1.7 to 3.4 lp/mm by using 10- μm-thick Pt-EMA; comparatively, using an array with thinner square fibers (50 μm) only obtains a resolution of 2.1 lp/mm. The packing fraction decreases with the increase of EMA thickness. Our results recommend the use of 10 μm Pt-EMA for the square and the cylindrical (hexagonal packing) scintillating fiber arrays with fibers of 50-200 μm in the cross-sectional dimension. Besides, the dead-zone material should be replaced by high-Z material for the hexagonal packing cylindrical fiber array with fibers of 50-200 μm in diameter. Tungsten (W) and gold (Au) are also used as EMA in the three fiber arrays as a comparison. The simulation results show that W can be used at a lower cost, and Au does not have any advantages in cost and resolution improvement.
This paper appears in: Nuclear Science, IEEE Transactions on, Issue Date: Dec. 2013, Written by: Qinggang Jia; Huasi Hu; Fengna Zhang; Tiankui Zhang; Wei Lv; Yuanpin Zhan; Zhihua Liu
© 2013 IEEE


http://ieeexplore.ieee.org/xpls/icp.jsp?arnumber=6678254
http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=06678254
合写作者:
Qinggang Jia, Huasi Hu, Fengna Zhang, et al.
卷号:
No.6, Vol.60
页面范围:
4727- 4736
是否译文:
发表时间:
2013-12-03