Switch loss of a frost-free refrigerator-freezer with parallel dual-evaporator refrigeration system and its mitigation
发布时间:2025-04-30    点击次数:

发布时间:2025-04-30

论文名称:Switch loss of a frost-free refrigerator-freezer with parallel dual-evaporator refrigeration system and its mitigation

发表刊物:Science and Technology for the Built Environment

摘要:The parallel dual-evaporator system has energy-saving potential in frost-free refrigerator-freezers, since it can provide proper
evaporating temperature difference for the refrigerator and the freezer, respectively. However, energy loss is generated during the
transition period of switches between refrigerating (R-) and freezing (F-) cycles in actual use. In this article, switch loss of a frost-free
refrigerator-freezer with parallel dual-evaporator refrigeration system is studied experimentally. Results show that the transition
process after F- to R-cycle switch takes 7.17 min and consists of three stages according to R-evaporator’s feeding: short feeding
(1.83 min), no feeding (2 min), and continuous feeding (3.34 min). The starvation in R-evaporator during the first two stages leads to
switch loss for the refrigerator-freezer, by consuming 23.3% electric energy but yielding only 6.9% capacity for an entire R-cycle.
The pump-down (P/D) action before R-cycles accelerates refrigerant’s pumping from F-evaporator and feeding to R-evaporator, thus
recovering part of the capacity loss. However, the introduction of P/D is not necessarily energy-efficient because P/D itself consumes
considerable electric energy. By contrast, R- to F-cycle switch has little effect on refrigerator-freezer performance due to instant
feeding. Dynamic simulation on the transition process will be provided in the future.

合写作者:赵日晶,黄东,彭学院,张耀吉

卷号:2019 (25)

页面范围:387-385

是否译文:

发表时间:2018-11-23